• TV UEL
  • slot gacor hari ini
  • 5080A High Compliance Multi-Product Calibrator – NA Caltechnologies Co.,Ltd. Skip to content
    +662-529-2460  |  086-788-3628  |  sales-cal@nacal.co.th  |  patamapornh@nacal.co.th
    • English
    Menu
    NA Caltechnologies Co.,Ltd.

    NA Caltechnologies Co.,Ltd.

    ×
    Member
      Cart 1   Quote 
    • Home
    • Products
    • Calibration
    • Service
    • Robotics
    • Contact Us
    ×
    • Home
    • Products
    • Calibration
    • Service
    • Robotics
    • Contact Us
    • English
    5080A High Compliance Multi-Product Calibrator
    “Fluke 725Ex Series Process Calibrator” has been added to your cart. View cart
    5080A High Compliance Multi-Product Calibrator

    5080A High Compliance Multi-Product Calibrator

    Accurate, reliable analog meter calibration

    The 5080A Multi-Product Calibrator calibrates your analog workload accurately and reliably, thanks to its high voltage and current compliance. With maximum burden up to 800 mA for ac/dc voltage, and voltage up to 50 V for ac/dc current, 5080A calibrators can drive a wide range of analog meters.

    Options and accessories expand workload coverage

    Options and accessories enable you to use the 5080A Multi-Product Calibrator to calibrate an even broader workload, including:

    • Clamp meters. The 9100-200 10/50 turn coil and 5500A/COIL 50-turn current coil enables the 5080A to calibrate most popular clamp meters at currents up to 1000 A rms amps.
    • Oscilloscopes. Oscilloscope calibration to 200 MHz quickly, easily, and cost effectively. Verify dynamic response, bandwidth, timing, multiple triggering functions, and input resistance.
    • Megohm meters. This option sources high ohms, high voltage resistors up to 18 G ohms. It also measures high voltage outputs.

    Protective circuits prevent damage

    Mains voltage inadvertently applied to a calibrator’s output terminals can cause extensive damage, requiring costly repairs. Electrical protection for calibrator outputs is vital for daily operation. The 5080A calibrator’s innovative protection circuitry prevents it from being damaged by reversed input voltage, so you can use it with confidence day after day.

    Highest voltage and current compliance

    The 5080A has the highest voltage and current compliance of any calibrator in the Fluke Calibration multi-product and multifunction calibrator families, making it an ideal solution for calibrating analog meters and other instruments requiring higher drive capability for proper operation.

    Maximum burden or compliance voltage
    Functions
    Model DC voltage AC voltage DC current AC current*
    5080A 600 mA 800 mA 50 V 44 V
    9100 20 mA 20 mA 4 V 4 V
    5500A 10 mA 10 mA 4.5 V 3 V
    5520A 10 mA 10 mA 7 V 5 V
    5700A 50 mA 50 mA 10 V 7 V
    5720A 50 mA 50 mA 10 V 7 V

    * With AC LCOMP on

    Automate the 5080A Multi-Product Calibrator to increase efficiency and throughput

    For the full spectrum of calibration automation and asset management, choose MET/CAL software

    The solutions you need, from the leader in calibration

    Fluke Calibration is a premium brand, well known around the world for its accurate, dependable, high quality products. Long known as a leader in dc and low frequency ac calibration, Fluke Calibration is also recognized for its offerings in temperature, pressure, power, process, and rf calibration. Fluke Calibration provides the calibrators, standards, software, service, support and training you need for a complete solution in your cal lab.

    Working...
    Product Added to Quote
    Remove from Quote
    Product Added to Quote
    Remove from Quote
    Category: Best Sellers & Hot Product Tag: Fluke
    • Product Overview
    • Models
    • Specifications
    • Resources

    Calibration solutions for your analog and digital workload

    • High compliance
    • Protection circuitry
    • Calibrates a wide workload, including analog meters and 3.5 and 4.5 digits DMMs

    The 5080A Multi-Product Calibrator calibrates your analog and digital workload accurately and economically. Its high voltage and current compliance makes analog workload calibration easy and precise. And built-in protection circuitry protects it against damaging input voltages.

    This easy-to-use multifunction calibrator can handle a wide meter calibration workload that includes:

    • Analog meters
    • Panel meters
    • Digital multimeters
    • Watt meters
    • Clamp meters (with coil accessory)
    • Megohm meters (optional)
    • Oscilloscopes to 200 MHz (optional)
    • …and more

    Versatile software applications enable you to record paperless results, and more. Best of all, the 5080A Multi-Product Calibrator offers this versatile functionality at a price that fits nicely into your budget.

    Model Name Description
    5080A Multi-Product Calibrator
    5080A/MEG Multi-Product calibrator with Megohm Meter Calibration Option
    5080A/SC Multi-Product Calibrator with Oscilloscope Calibration Option
    5080A/SC/MEG Multi-Product Calibrator with Megohm Meter and Oscilloscope Calibration Option

    Accessories common to all models:

    Accessory Description
    9100-200 10/50 Turn Current Coil
    5500A/COIL 50-Turn Current Coil
    5080A/MEG 5080A Megohm Meter Calibration Option
    5080A/CASE 5080A/CASE
    5080A -> 5080A/SC/MEG Upgrade 5080A to 5080A/SC/MEG – Installable only at Fluke service centers for extra installation and calibration cost.
    5080A -> 5080A/MEG Upgrade 5080A to 5080A/MEG – Installable only at Fluke service centers for extra installation and calibration cost.
    Silver CarePlan Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote.
    Priority Gold Instrument CarePlan Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote.
    Technical Specifications
    Voltage DC
    Range: 0 to ±1020V
    Best 1 Year Specification: ±0.01% of setting
    Current DC
    Range: 0 to ±20.5A
    Best 1 Year Specification: ±0.05% of setting
    Resistance
    Range: 0 to 190 MO, 19 values in x1 and x1.9
    Best 1 Year Specification: ±0.025% of setting
    Voltage AC
    Range: 1 mV to 1020V
    45Hz to 1 kHz, Sine
    Best 1 Year Specification: ±0.1% of setting
    Current AC
    Range:29 mA to 20.5A
    45 Hz to 1 kHz, Sine
    Best 1 Year Specification: ±0.1% of setting
    DC Power
    Range:10.9 mW to 20.5 kW
    Best 1 Year Specification: ±0.11% of setting
    AC Power
    Range: 10.9 mW to 20.5 kW
    45-65 Hz, PF=1
    Best 1 Year Specification: ±0.36% of setting
    Phase
    Range: 0 to ± 179.99°
    45 Hz to 1 kHz
    Best 1 Year Specification: ±0.25° of setting
    Frequency
    Range: 45 Hz to 1 kHz
    Best 1 Year Specification: ±50 ppm of setting
    General Specifications
    Warm up Time
    Twice the time since last warmed up, to a maximum of 30 minutes
    Settling Time
    Less than 5 seconds for all functions and ranges except as noted
    Standard Interfaces
    RS-232 and Ethernet
    Temperature Performance
    Operating: 0°C to 50°C
    Calibration (tcal):15°C to 35°C
    Storage:-20°C to +70°C
    Temperature Coefficient
    Temperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C.
    Relative Humidity
    Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C
    Storage:<95%, non-condensing
    Altitude
    Operating: 2,000m (6,500 ft) maximum
    Non-operating: 12,200m (40,000 ft) maximum
    Safety
    Meets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004
    Analog Low Isolation
    20V
    EMC
    Meets EN613261:2006.
    Line Power
    Line Voltage (selectable): 100V, 120V, 220V, 240V
    Line Frequency: 47 to 63 Hz
    Line Voltage Variation: + 10% about line voltage setting
    Power Consumption
    600 VA
    Calibration Documentation Report of calibration with data included; 17025 accredited report optional
    Dimensions
    Height:19.3 cm (7.6 in)
    Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles
    Depth:53.8 cm (21.2 in)
    Weight (without options)
    22 kg (48 lbs.)
    Absolute Uncertainty Definition
    The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated.
    Specification Confidence Interval
    99%

    Related products

    Fluke TL175 TwistGuard™ Test Leads

    Fluke TL175 TwistGuard™ Test Leads

    ฿1,410.00
    Add to cart
    Fluke TP82 Insulation Piercing Clip Set

    Fluke TP82 Insulation Piercing Clip Set

    ฿3,075.00
    Add to cart
    Fluke TP2 Slim Reach Test Probes

    Fluke TP2 Slim Reach Test Probes

    ฿1,025.00
    Add to cart

    Product Categories

    • Best Sellers & Hot Product
    • Accessories
      • Adapters
      • Automotive
      • Batteries
      • Cables
      • Cases and Holsters
      • Chargers
      • Connectors
      • Current Clamps
      • Current Probes
      • Fiber Optics
      • Hardware
      • High Voltage Probes
      • IR Lenses
      • Kits
      • Lights
      • Other
      • Pressure
      • Probes
      • Pumps
      • Rack Mounts
      • Software
      • Test leads, Probes and Clips
      • Thermal Imaging
      • Thermometer
    • Building Infrastructure
      • HVAC Tools
      • Indoor Air Quality Testing
      • Laser Distance Meters
      • Laser Levels
    • Calibration Tools
      • mA Loop Calibrators
      • Multifunction Calibrators
      • Pressure Calibrators
      • Temperature Calibrators
    • Electrical Tools
      • Basic Electrical Testers
      • Clamp Meters
      • Digital Multimeters
      • Installation Testers
      • Insulation Testers
      • Portable Appliance Testers
      • Portable Oscilloscopes
      • Power Quality
    • Industrial Imaging
    • Intrinsically Safe
    • Mechanical Maintenance
      • Laser Alignment
      • Vibration Analysis
    • Temperature Measurement
      • Contact Thermometers
      • IR Thermometers
    • Thermal Imaging
      • IR Windows
      • Thermal Cameras
      • Visual IR Thermometers

    NA Caltechnologies Co.,Ltd.

    75/107 Moo 11, Paholyothin Rd., Klongnueng, Klongluang, Pathumthani 12120, Thailand

    +662-529-2460 (Auto)

    Sales-cal@nacal.co.th

    sales-product@nacal.co.th

    Facebook Line
    Menu
    • Home
    • Products
    • Calibration Laboratory
    • Service
    • Robotics and System Integration
    • Articles
    Member
    • Login
    • Register
    • My Account
    • My Orders
    • Confirm Payment
    About Us
    • Accreditation Certificate
    • Company Profile
    • Contact Us

    เข้าสู่ระบบ