| AC Voltage |
| Range 1 |
Resolution |
Accuracy 2 3 4 |
Accuracy 2 3 4 |
| 45 Hz to 500 Hz |
500 Hz to 1 kHz |
| 600.0 mV |
0.1 mV |
1.0% + 3 |
2.0% + 3 |
| 6.000 V |
0.001 V |
| 60.00 V |
0.01 V |
| 600.0 V |
0.1 V |
| 1000 V |
1 V |
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz. |
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance |
| Function |
Range |
Resolution |
Accuracy |
| mV |
600.0 mV |
0.1 mV |
0.09% + 2 |
| V |
6.000 V |
0.001 V |
0.09% + 2 |
| 60.00 V |
0.01 V |
| 600.0 V |
0.1 V |
| 1000 V |
1 V |
0.15% + 2 |
| Ω |
600 Ω |
1 Ω |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
| Ω |
600.0 Ω |
0.1 Ω |
0.5% + 2 |
| 6.000 kΩ |
0.001 kΩ |
0.5% + 1 |
| 60.00 kΩ |
0.01 kΩ |
| 60.00 kΩ |
0.1 kΩ |
| 600.0 kΩ |
0.001 MΩ |
| 50.00 MΩ |
0.01 MΩ |
1.5% + 3 |
| Diode test |
2.000 V |
0.001 V |
1% + 2 |
| µF |
1000 nF |
1 nF |
1.2% + 2 |
| 10.00 μF |
0.01 μF |
| 100.0 μF |
0.1 μF |
| 9999 μF1 |
1 μF |
10% typical |
| 1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. |
| AC and DC Current |
| Function |
Range 1 |
Resolution |
Accuracy |
mA AC
(45 Hz to 1 kHz) |
60.00 mA |
0.01 mA |
1.5% + 3 |
| 400.0 mA 3 |
0.1 mA |
| mA DC 2 |
60.00 mA |
0.01 mA |
0.5% + 3 |
| 400.0 mA 3 |
0.1 mA |
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload. |
| Frequency |
| Range |
Resolution |
Accuracy 1 |
| 99.99 Hz |
0.01 Hz |
0.1% + 1 |
| 999.9 Hz |
0.1 Hz |
| 9.999 kHz |
0.001 kHz |
| 99.99 kHz |
0.01 kHz |
| 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. |
| Input Characteristics |
| Function |
Overload
protection |
Input impedance
(nominal) |
Common mode rejection ratio
(1 kΩ unbalance) |
Normal mode rejection |
 |
1100 Vrms |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
 |
1100 Vrms |
> 10 MΩ < 100 pF |
> 60 dB, DC to 60 Hz |
|
 |
1100 Vrms |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
| Open circuit test voltage |
Full scale voltage |
Typical short circuit current |
| To 6 MΩ |
50 MΩ |
 |
1100 V RMS |
< 2.7 VDC |
< 0.7 VDC |
< 0.9 VDC |
< 350 mA |
 |
1100 Vrms |
< 2.7 VDC |
2.000 VDC |
< 1.1 mA |
| mA Function |
| Overload Protection |
Fused, 44/100 A, 1000 V FAST Fuse |
| Overload |
600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
| MIN/MAX Recording Accuracy |
| DC functions |
The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. |
| AC functions |
The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
| General Specifications |
| Maximum voltage between any terminal and earth ground |
1000 VDC or AC rms |
| Ω fuse protection from A inputs |
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
| Display (LCD) |
Update rate |
4/sec |
| Volts, amps, ohms |
6000 counts |
| Frequency |
10,000 counts |
| Capacitance |
1,000 counts |
| Battery type |
Three AA Alkaline batteries, NEDA 15A IEC LR6 |
| Battery life |
250 hours minimum |
| RF communications |
2.4 GHZ ISM Band |
| RF communication range |
Open air, unobstructed |
Up to 20 m |
| Obstructed, sheetrock wall |
Up to 6.5 m |
| Obstructed, concrete wall, or steel electrical enclosure |
Up to 3.5 m |
| Temperature |
Operating |
-10°C to 50°C |
| Storage |
-40°C to 60°C |
| Temperature coefficient |
0.1 x (specified accuracy) / °C (< 18°C or > 28°C) |
| Relative humidity |
0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C) |
| Altitude |
Operating |
2,000 m |
| Storage |
12,000 m |
Electromagnetic compatibility
EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
| Safety compliance |
ANSI/ISA 61010-1 / (82.02.01) |
3rd edition |
| CAN/CSA-C22.2 No 61010-1-12 |
3rd edition |
| UL 61010-1 |
3rd edition |
| IEC/EN 61010-1 |
2010 |
| Certifications |
CSA, FCC, CE |
| Ingress Protection (IP) rating |
IP54 |
| Pollution degree |
2 |
| Size (H x W x L) |
4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) |
| Weight |
340 g (12 oz) |
| Warranty |
Three years |
| Not compatible with Fluke CNX test tools |