| AC Voltage | 
| Range¹ / resolution |  | 600.0 mV / 0.1 mV 6.000 V / 0.001 V
 60.00 V / 0.01 V
 600.0 V / 0.1 V
 1000 V / 1 V
 | 
| Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 | 
| 500 Hz to 1 kHz | 2.0% + 3 | 
| 1. All AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
 4. Do not exceed 107 V-Hz.
 | 
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance | 
| mV | Range / resolution | 600.0 mV / 0.1 mV | 
| Accuracy | 0.09% + 2 | 
| V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V
 600.0 V / 0.1 V
 1000 V / 1 V
 | 
| Accuracy | 0.09% + 2 0.15% + 2
 | 
| ))) | Range / resolution | 600 Ω / 1 Ω | 
| Accuracy | Meter beeps at | 
| Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ
 60.00 kΩ / 0.01 kΩ
 60.00 kΩ / 0.1 kΩ
 600.0 kΩ / 0.001 MΩ
 50.00 MΩ / 0.01 MΩ
 | 
| Accuracy | 0.5% + 2 0.5% + 1
 1.5% + 3
 | 
| Diode test | Range / resolution | 2.000 V / 0.001 V | 
| Accuracy | 1% + 2 | 
| µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF
 100.0 μF / 0.1 μF
 9999 μF1 / 1 μF
 | 
| Accuracy | 1.2% + 2 10% typical
 | 
| 1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | 
| AC and DC Current | 
| mA AC (45 Hz to 1 kHz)
 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA
 | 
| Accuracy | 1.5% + 3 | 
| mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3/ 0.1 mA
 | 
| Accuracy | 0.5% + 3 | 
| 1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA.
 3. 400.0 mA accuracy specified up to 600 mA overload.
 | 
| Frequency | 
| Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz
 9.999 kHz / 0.001 kHz
 99.99 kHz / 0.01 kHz
 | 
| Accuracy1 | 0.1% + 1 | 
| 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | 
| Input Characteristics | 
|  | Overload protection | 1100 Vrms | 
| Input impedance (nominal) | > 10 MΩ | 
| Common mode rejection ratio (1 kΩ unbalance)
 | > 120 dB at DC, 50 Hz or 60 Hz | 
| Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | 
|  | Overload protection | 1100 Vrms | 
| Input impedance (nominal) | > 10 MΩ | 
| Common mode rejection ratio (1 kΩ unbalance)
 | > 60 dB, DC to 60 Hz | 
| Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | 
|  | Overload protection | 1100 Vrms | 
| Input impedance (nominal) | > 10 MΩ | 
| Common mode rejection ratio (1 kΩ unbalance)
 | > 120 dB at DC, 50 Hz or 60 Hz | 
| Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | 
| Open Circuit Test Voltage | 
|  | Overload protection | 1100 Vrms | 
| Input impedance (nominal) |  | 
| Full scale voltage to 6 MΩ Full scale voltage 50 MΩ
 |  | 
| Typical short circuit current |  | 
|  | Overload protection | 1100 Vrms | 
| Input impedance (nominal) |  | 
| Full scale voltage to 6 MΩ Full scale voltage 50 MΩ
 | 2.000 VDC | 
| Typical short circuit current |  | 
| mA Function | 
| Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | 
| Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | 
| MIN/MAX Recording Accuracy | 
| DC functions | ±12 counts for changes > 350 mS in duration. | 
| AC functions | ±40 counts for changes > 900 mS in duration. | 
| General Specifications | 
| Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | 
| Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | 
| Display (LCD) | Update rate | 4/sec | 
| Volts, amps, ohms | 6000 counts | 
| Frequency | 10,000 counts | 
| Capacitance | 1,000 counts | 
| Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | 
| Battery life | 250 hours minimum | 
| RF communications | 2.4 GHZ ISM Band | 
| RF communication range | Open air, unobstructed | Up to 20 m | 
| Obstructed, sheetrock wall | Up to 6.5 m | 
| Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5 m | 
| Temperature | Operating | -10°C to 50°C | 
| Storage | -40°C to 60°C | 
| Temperature coefficient | 0.1 x (specified accuracy) / °C ( 28°C) | 
| Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C)
 0% to 45% (40°C to 50°C)
 | 
| Altitude | Operating | 2,000 m | 
| Storage | 12,000 m | 
| Electromagnetic compatibility EMI, RFI, EMC, RF
 | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
 V1.8.1:2008
 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
 | 
| Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition
 UL 61010-1: 3rd edition
 IEC/EN 61010-1:2010
 | 
| Certifications | CSA, FCC, CE | 
| Ingress Protection (IP) rating | IP54 | 
| Pollution Degree | 2 | 
| Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | 
| Weight | 340 g (12 oz) | 
| Warranty | Three years | 
| Not compatible with Fluke CNX test tools |