Technical Specifications
Voltage DC
Range:  0 to ±1100V
5700A Best 1 Year Specification:  ±7.0 ppm of setting
5720A Best 1 Year Specification:  ±3.5 ppm of setting
Voltage AC
Range:  0.22 µV to 1100V
 10 Hz to 1 MHz
5700A Best 1 Year Specification:  ±75.0 ppm of setting
5720A Best 1 Year Specification:  ±45.0 ppm of setting
Resistance
Range:  0 to 100 MΩ, 18 values in x1 and x1.9
5700A Best 1 Year Specification:  ±12.0 ppm
5720A Best 1 Year Specification:  ±8.5 ppm
Current DC
Range:  0 to ±2.2A (11A with 5725A)
5700A Best 1 Year Specification:  ±50 ppm of setting
5720A Best 1 Year Specification:  ±35 ppm of setting
Current AC
Range:  9 µA to 2.2A (11A with 5725A) 10 Hz to 10 kHz
5700A Best 1 Year Specification:  ±140 ppm of setting
5720A Best 1 Year Specification:  ±120 ppm of setting
Wideband AC Voltage Option
Range:  300 µV to 3.5V
 10 Hz to 30 MHz
5700A Best 1 Year Specification:  ±0.4% of setting
5720A Best 1 Year Specification:  ±0.4% of setting
General Specifications
Warm up Time
 2x the time since last warmed up, to a maximum of 30 minutes
System Installation
 Rear output configuration and rack-mount kit available
Interfaces
 IEEE-488, RS-232, 5725A, 5205A or 5215A, 5220A, phase lock in (BNC), phase reference out (BNC)
Temperature Performance
Operating:  0°C to 50°C
Calibration:  15°C to 35°C
Storage:  -40°C to 75°C
Relative Humidity
Operating:  < 80% to 30°C, < 70% to 40°C, < 40% to 50°C
Storage:  < 95%, non-condensing. A power-on stabilization period of four days may be required after extended storage at high temperature and humidity.
Safety
 Designed to comply with UL311; IEC 348-1978; IEC 66E (CO)4; CSA 556B
Guard isolation
 20 volts
EMI/RFI
 Designed to comply with FCC Rules Part 15, Subpart J, Class B; VDE 0871, Class B
Line Power
 47 to 63 Hz; + 10% allowed about selectable nominal line voltage: 100V, 110V, 115V, 120V, 200V, 220V, 230V, 240V
 ————–
Maximum power:  5700A/5720A: 300 VA;5725A, 750 VA
Calibration Documentation 17025 accredited report of calibration included
Size
5700A/5720A:  Height 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet; width 43.2 cm (17 in), standard rack width; depth 63.0 cm (24.8 in) overall; 57.8 cm (22.7 in), rack depth
5725A:  Height 13.3 cm (5.25 in); width and depth same as 5700A/5720A
 Both units project 5.2 cm, (2 in) from rack front
Weight
5700A/5720A:  27 kg (62 lbs.)
5725A:  32 kg (70 lbs.)